MatriX-1
Ultrafast photoluminescence spectrometer
Features
400 - 875 nm single frame detection
Femtosecond temporal resolution
Adjustable repetition rate
High data quality
Rapid data acquisition
Straightforward alignment
User-friendly interface
About
The MatriX-1 is the world’s first ultrafast broadband photoluminesence spectrometer for amplified lasers. It uses transient grating technology to achieve background-free and broadband fluorescence detection with femtosecond temporal resolution.
The sensitive detection scheme can measure the smallest of signals. This high sensitivity is intrinsic to the transient grating configuration, along with optical design that enhances the gated fluorescence throughput and blocks background light.
This turnkey system comes with intuitive software that includes alignment tools, custom time series builder, data acquisition and processing, and real-time data acquisition display.
Features
Simultaneous detection of a broadband emission spectrum, covering 400 - 875 nm
fs resolution with the instrument response function being 1.6 times the longest pulse duration
High data quality due to the background free configuration and high repetition-rate compatibility
Rapid data acquisition enabled by the broadband detection and high gating efficiency
Minimal alignment required using straightforward alignment checkpoints
User-friendly software interface guides the user through the experimental steps
Compatible with both amplified Ti:Sapphire and Yb fiber and solid-state laser systems
Easily integrated with the TAngent-1 – Advemto’s forthcoming ultrafast transient absorption
Applications
Semiconductors
Organic semiconductors
Stimulated emission
Photochemistry
Biology
Nanoscience
Photonics
Specifications
Detection
400 nm - 875 nm, single frame
High throughput broadband spectrometer
Supressed background from laser harmonics
10 ms - 60 s integration time
20 bit cooled back-thinned CCD
Delay line
600 ps - 8 ns total range
Temporal resolution
1.6 times the pulse duration
Dimensions
W450 x L860 x H250 mm
Externally mounted spectrometer and CCD:
W320 x L140 x H220 mm
Sample type
Solution, thin film, powder and single crystals
Interface
Laptop or NUC with pre-installed software
Options
Sample mounting
Sample translation, magnetic stirrer and/or active vacuum holder
UV or IR enhanced (Coming soon)
Shifts the detectable range to specific emission regions
Cryostat (Coming soon)
For temperature dependent measurements
Automated alignment (Coming soon)
Automation of key alignment steps and experimental operations
Software
The stepwise software creates an easy-to-follow workflow.
Alignment cameras to guide the user through straightforward alignment checks.
Custom time series for material-specific temporal resolution and time window.
Real-time acquisition display to verify the signal while the measurement is running.
Documentation
Publications
Using Advemto’s transient grating technology: