MatriX-1

Ultrafast photoluminescence spectrometer


Features

MatriX-1 ultrafast photoluminesence spectrometer
  • 400 - 875 nm single frame detection

  • Femtosecond temporal resolution

  • Adjustable repetition rate

  • High data quality

  • Rapid data acquisition

  • Straightforward alignment

  • User-friendly interface

About

The MatriX-1 is the world’s first ultrafast broadband photoluminesence spectrometer for amplified lasers. It uses transient grating technology to achieve background-free and broadband fluorescence detection with femtosecond temporal resolution.

The sensitive detection scheme can measure the smallest of signals. This high sensitivity is intrinsic to the transient grating configuration, along with optical design that enhances the gated fluorescence throughput and blocks background light.

This turnkey system comes with intuitive software that includes alignment tools, custom time series builder, data acquisition and processing, and real-time data acquisition display.

Features

  • Simultaneous detection of a broadband emission spectrum, covering 400 - 875 nm

  • fs resolution with the instrument response function being 1.6 times the longest pulse duration

  • High data quality due to the background free configuration and high repetition-rate compatibility

  • Rapid data acquisition enabled by the broadband detection and high gating efficiency

  • Minimal alignment required using straightforward alignment checkpoints

  • User-friendly software interface guides the user through the experimental steps

  • Compatible with both amplified Ti:Sapphire and Yb fiber and solid-state laser systems

  • Easily integrated with the TAngent-1 – Advemto’s forthcoming ultrafast transient absorption

Applications

  • Semiconductors

  • Organic semiconductors

  • Stimulated emission

  • Photochemistry

  • Biology

  • Nanoscience

  • Photonics


Specifications

Detection
400 nm - 875 nm, single frame
High throughput broadband spectrometer
Supressed background from laser harmonics
10 ms - 60 s integration time
20 bit cooled back-thinned CCD

Delay line
600 ps - 8 ns total range

Temporal resolution
1.6 times the pulse duration

Dimensions
W450 x L860 x H250 mm
Externally mounted spectrometer and CCD:
W320 x L140 x H220 mm

Sample type
Solution, thin film, powder and single crystals

Interface
Laptop or NUC with pre-installed software

Options

Sample mounting
Sample translation, magnetic stirrer and/or active vacuum holder

UV or IR enhanced (Coming soon)
Shifts the detectable range to specific emission regions

Cryostat (Coming soon)
For temperature dependent measurements

Automated alignment (Coming soon)
Automation of key alignment steps and experimental operations

Software

  • The stepwise software creates an easy-to-follow workflow.

  • Alignment cameras to guide the user through straightforward alignment checks.

  • Custom time series for material-specific temporal resolution and time window.

  • Real-time acquisition display to verify the signal while the measurement is running.

Documentation